VMS-2000 Series

Blast Monitoring Seismograph

Geonoise Noise registration instruments and software

Geonoise Thailand Co., Ltd.
Address: 555/147-148 Sukhapiban 5
10220 Sai Mai, Bangkok, Thailand
Phone: (+66) 02-0035904
Fax: (+66) 02-0033054
E-Mail: contact@geonoise.com
Website: http://www.geonoise.com

For blast monitoring (mining), a blast monitoring seismograph. The VMS-2000 series is a complete set, so you don’t need anything more to get started.

The mining blast monitoring set holds:

 

  • External Geophone
  • Battery Charger
  • Microphone with stand
  • Seisware analysis software
  • Soft Carrying Case

Some features: VMS-2000 System Features

 

  • Computer or Field Programmable
  • Low Cost and Versatile
  • Highly Reliable
  • Microphone with full height stand
  • Fast Recycle Time
  • Internal Time and Date
  • Low Power Consumption
  • Trigger Mode Operation
  • External Geophones
  • Free Seisware Analysis Software
  • Standard 9-pin RS-232 serial port
  • Easy to use 4-key switch pad
  • 100 Full Waveform storeage
  • Store and view last 96 summary events

VMS-2000 Field Operations

The VMS-2000 is configured for operation using the supplied SeisWare program for Windows. The trigger source, trigger level and record time are selected using the SeisWare for Windows Software, and then downloaded to the VMS-2000 unit via the serial port using the included communications cable. The configuration (setup) of the VMS-2000 is stored in non-volatile memory so that the unit can be operated without bringing the PC into a dirty and possible hazardous environment. After connecting the geophone and installing the spikes, turn the VMS-2000 on and press the MONITOR switch. When a vibration or sound land triggers the instrument, the resulting digital data is automatically stored in non-volatile memory on the VMS-2000 and the instrument returns to monitoring the input signals until the trigger level is reached again. After monitoring is finished, press the ENTER key to discontinue monitoring. When convenient, connect the VMS-2000 to your PC and download the data using the Seisware software for permanent storage. The VMS-2000 can also be a stand alone unit, having the ability to recall the last 96 events.

VMS-2000 Field Operations

System

Display:

4 line by 20 columns LCD

Resolution Seismic:

0.0050/in/s (0.127 mm/s); Acoustic: 1 dB

Sample Rate:

1024 Samples per Second

Geophone:

Triaxial, 4.5 Hz Natural Frequency

Microphone:

Ceramic, 5 ft (1.5 in) Neoprene Cable

Operations

Units of Measure: English or Metric

Seismograph Operation:

Trigger Source

Geophone or Microphone

Trigger Level:

GEO .02 – 2.00 in/s (.51-50.8mm/s)

Trigger Level:

MIC 100, 105, 110, 115, 120, 125, 129dB

Range:

Full Autoranging

Seismic:

0.00-9.00 in/s (0-228.6 mm/s)

Acoustic:

86-141 dB (re 2.9 x 10psi)

Modes:

Multiple Event ( with Full Waveforms)

Record Time:

1 to 10 seconds in ls increments, plus 0.5s Pre-trigger

Environmental:

Operation Temperature Range: -15c to +50c

Physical Dimensions:

L 9.3 in. x W 7.2 in. x D 4.1 in. L23.6 cm x W 18.3 cm x D 10.5 cm

Weight:

14lbs

 

  • Model: 380-0075
  • Shipping Weight: 14lbs
  • Manufactured by: Thomas Instruments