System:
Display: 128 by 64 Pixel Graphic LCD (8 line by 20 Column)
Resolution: Seismic 0.00125 in/s (0.03175 mm/s); Acoustic 1dB
Sample Rate: 1024 Samples per Second Stored
Frequency Responses: 2 to 350 Hz (-3dB)
Geophone: Triaxial, 4.5 Hz Natural Frequency
Seismograph Operation:
Trigger Source: Geophone and/or Microphone and/or Manually
Trigger Level: Geo; .02 – 2.00 in/s (.51 – 50.8 mm/s)
Mic; 100, 105, 110, 115, 120, 125, or 129 dB
Range: Full Autoranging
Seismic: 0.00 – 9.00 in/s (0 – 288.6 mm/s)
Acoustic: 86 – 141 dB (re 2.9 x 10-9 psi)
Modes: Multiple Event with Full Waveforms
Record Time: 1 to 10 Seconds in One Sec Increments w/ Half Sec Pre-Trigger
Operational Temperature Range: 5°f – 122°f
-15°c – 50°c
Physical Dimensions: L 7.5in x W 5.9in x D 2.4in
L 10cm x W 15cm x D 6cm
Weight: Main; 1.6 lbs., Geo; 2.4 lbs., Mic; 0.5 lbs.
Main; .7 kg, Geo, 1.1 kg, Mic, .23 kg